YOU ARE AT THE INTERNATIONAL WEBSITE, SWITCH TO: | nl NETHERLANDS | usa USA |  
   
 
 
 
SMD-CC
Through Bolt Anchor
 
 

SMD-CC Product Dimensions

SMD-CC Da   M8 M10 M12 M16 M20
Min. Anchor Length L,min [mm] 68 82 98 119 140
Max. Anchor Length L,max [mm] 200 200 250 250 300
Hexagon Nut SW [mm] 13 17 19 24 30


SMD-CC Installation Dimensions

SMD-CC Da   M8 M10 M12 M16 M20
Diameter Bore Hole d0 [mm] 8 10 12 16 20
Drilling Depth h1 [mm] 60 75 85 105 125
Overall Embedment Depth hnom [mm] 55 68 80 97 114
Eff. Anchorage Depth hef [mm] 48 60 70 85 100
Diameter Fixture Hole df [mm] 9 12 14 18 22
Fixture Height tfix [mm] L-66 L-80 L-96 L-117 L-138
Recommended Torque Tinst [Nm] 20 40 60 100 200


SMD-CC Member Thickness, Edge Distance & Spacing

SMD-CC Da   M8 M10 M12 M16 M20
Min. Member Thickness hmin [mm] 100 120 140 170 200
Min Edge Distance Cmin [mm] 50 60 70 85 100
Min. Spacing Smin [mm] 50 60 70 85 100


SMD-CC Installation Procedures


SMD-CC Design Loads1)

Steel Failure



Non Cracked Concrete Da   M8 M10 M12 M16 M20
Zinc Plated Tensile NRd [kN] 5,0 10,7 13,3 23,3 33,3
Shear2) VRd [kN] 8,8 13,9 20,2 37,7 58,5
Sherardized Tensile NRd [kN] 5,0 10,7 19,7 23,3 33,3
Shear2) VRd [kN] 8,8 13,9 20,2 37,7 58,5
                 
Cracked Concrete Da   M8 M10 M12 M16 M20
Zinc Plated Tensile NRd [kN] 2,8 6,0 8,0 16,7 20,0
Shear2) VRd [kN] 8,0 13,9 20,2 37,7 48,0
Sherardized Tensile NRd [kN] 3,3 6,0 10,7 16,7 20,0
Shear2) VRd [kN] 8,0 13,9 20,2 37,7 48,0


SMD-CC Recommended Loads3)

Steel Failure



Non Cracked Concrete Da   M8 M10 M12 M16 M20
Zinc Plated Tensile NRec [kN] 3,6 7,6 9,5 16,7 23,8
Shear2) VRec [kN] 6,3 9,9 14,5 26,9 41,8
Sherardized Tensile NRec [kN] 3,6 7,6 14,1 16,7 23,8
Shear2) VRec [kN] 6,3 9,9 14,5 26,9 41,8
                 
Cracked Concrete Da   M8 M10 M12 M16 M20
Zinc Plated Tensile NRec [kN] 2,0 4,3 5,7 11,9 14,3
Shear2) VRec [kN] 5,7 9,9 14,5 26,9 34,3
Sherardized Tensile NRec [kN] 2,4 4,3 7,6 11,9 14,3
Shear2) VRec [kN] 5,7 9,9 14,5 26,9 34,3

1) All Loads in kN for a Single anchor in Dry/Wet concrete C20/25 without edge or spacing influences. 2) Steel strength in kN without bending moment. 3) Incl. Safety factor γG = 1,4

 

 

Logo B+BTec

   
Contact General Products
Munterij 8 Privacy & Cookie Statement Core Drilling
4762 AH Zevenbergen On-Site with B+BTec Structural Anchoring
  Website B+BTec Netherlands Concrete Cutting
The Netherlands Website B+BTec USA Hammer Drilling
    Tile & Stone
T +31 168 331 260    
F +31 168 331 280   Folow us on:
E info@bbtectools.com
   
© Copyright 2010-2021 B+BTec. All Rights Reserved. B+BTec, Karat & Diamond3 are Registered Trademarks.